4.4 Failsafe Alarm Relay Wiring
The “Failsafe” output relay is provided to signal critical error conditions that may occur on the
RSG2000 series switches. The contacts are energized upon power up of the unit and remain
energized until a critical error occurs. The proper relay connections are shown in Figure 12.
Control of the output is user selectable and can be programmed via the Rugged Operating System
(ROS). One common application for this output is to signal an alarm if a power failure or removal of
control power occurs.
Figure 12: Failsafe Alarm Relay Wiring
18
© 2008 RuggedCom Inc. All rights reserved Rev105